The main function of the high-pressure vacuum contactor is to operate the large load current frequently, especially suitable for harsh environment and flammable and explosive dangerous places.

The working principle of the high pressure vacuum contactor is similar to that of the low pressure contactor, the contactor is drawn by charging the coil, and the contactor returns when the coil is out of power. The main difference is that the high-pressure vacuum contactor can be operated on and off in a vacuum environment, and the vacuum arc extinguishing chamber is used to extinguish the arc, which is suitable for the on-off of high voltage and large current.

The high voltage vacuum contactor is designed to operate without protection, similar to the switch on a household light, it cannot disconnect the short circuit current, so it is often used in conjunction with a high voltage vacuum circuit breaker to provide more comprehensive circuit protection. Because of its small size, light weight, frequent operation and other characteristics, this equipment is widely used in a variety of frequent operation fields, including power system, metallurgy, mining, rolling stock, rail transit and other industries of high voltage equipment, to ensure the safety of equipment and personnel.

 

 

 

Request a Quote

PRODUCTS DETAILS

The high voltage vacuum contactor is designed to operate without protection, similar to the switch on a household light, it cannot disconnect the short circuit current, so it is often used in conjunction with a high voltage vacuum circuit breaker to provide more comprehensive circuit protection. Because of its small size, light weight, frequent operation and other characteristics, this equipment is widely used in a variety of frequent operation fields, including power system, metallurgy, mining, rolling stock, rail transit and other industries of high voltage equipment, to ensure the safety of equipment and personnel.

 

1.png

 

 

Technical parameters:

NO.

Parameters

Unit

Value

BKZC(R)-12-630/400/250

BKZC(R)-12-630/400/250

1

Rated Voltage

kV

7.2

12

2

Rated Current

A

630

400

250

630

400

250

3

Rated closing current (rms)

A

6300

4000

2500

6300

4000

2500

4

rated breaking current

5040

3200

2500

5040

3200

2500

5

4S thermal current

6300

4000

2500

6300

4000

2500

6

Limit breaking current

6300

4000

2500

6300

4000

2500

7

Power frequency withstand voltage

kV

32

42

8

operating frequency

Times/h

300

9

Electric life time

AC-3

×10Times

25

AC-4

10

10

Mechanical life

30

11

Rated operating voltage

V

AC110/220

12

Closing coil pull current

A

≤ DC6/3

13

Holding coil holding current

D:DC0.32/0.16

14

Shunt trip coil current

J:DC2.5/1.3

 

 