8615167740056

SCB11 10/0.4KV Dry type Power transformer

Dry-type transformer is mainly composed of high magnetic permeability silicon steel core and epoxy
resin cast coil. Its main advantages are: safety, fire prevention, no pollution, and can be directly run in
the load center; high mechanical strength, strong short-circuit resistance, Small partial discharge, good
thermal stability, high reliability, long service life; low loss, low noise, significant energy saving effect, and
maintenance-free.

Request a Quote

PRODUCTS DETAILS

Top quality comes first; services is foremost; organization is cooperation" is our small business philosophy which is regularly observed and pursued by our company for Bottom price Core-Type Toroidal Fast Delivery Existing Goods Multiple Certifications Wholesale Hot Sale Transformer, As a result of our hard perform, we have always been around the forefront of clean technology merchandise innovation. We've been a eco-friendly partner you can rely on. Get hold of us today for additional data! Bottom price Pad Mounted Transformer and 12V Toroidal Transformer, our qualify goods have good reputation from the world as its most competive price and our most advantage of after-sale service to the clients.we hope we can present a safe, environmental products and solutions and super service to our clients from all of the world and establish strategic partnership with them by our specialist standards and unremitting efforts.

The overall structure of the circuit breaker is simple and reasonable, and the arc extinguishing chamber part, interlock part and operating part are arranged up and down. Special spring operating mechanism, no need to adjust, stable and reliable action.The installation form is free and flexible, including the drawout type of installation and fixed type of installation for switchgears.

Environmental conditions:

  1. Altitude: the altitude does not exceed 2000m;
  2. Ambient temperature: no higher than +40℃, not lower than -25℃;
  3. Relative humidity: the daily average does not exceed 95%, and the monthly average does not exceed 90%;
  4. Earthquake intensity: no more than 8 degrees;
  5. Locations without fire, explosion hazard, serious contamination, chemical corrosion and severe vibration.

Technical parameters

Name

Unit

Value

Rated voltage

KV

40.5

1min power frequency withstand voltage

KV

95

Lightning impulse withstand voltage

KV

185

Rated frequency

Hz

50

Rated current

A

1250,1600,2000

Rated short-time withstand current

KA

25,31.5

Rated peak withstand current

KA

63,80

Rated short circuit duration

S

4

Rated short-circuit breaking current

KA

25,31.5

Rated short circuit closing current

KA

63,80

Rated operation sequence

 

0-0.3s-Co-180s-Co

Break time

ms

<80

Rated operating voltage

V

~110/-110,~220/-220

Mechanical life

time

10000

12.png

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return