8615167740056

Switchgear (RMU)12kv 24kv 40.5kv XGN66-12 10KV VCB Ring Main Unit

XGN66-12 Medium voltage AC switchgear fixed type metal-enclosed switchgear applied to the 3.6kV~35kV three phase AC 50/60Hz system to receive and distribution power energy

Request a Quote

PRODUCTS DETAILS

The incredibly rich projects administration experiences and a person to 1 service model make the substantial importance of organization communication and our easy understanding of your expectations for Good Quality High Voltage Ring Main Unit Switchgear, Rmu Switchgear, Cubicle Switchgear, Compact Switchgear, Gas Switchgear for Transformer Substation Xgn 80-12-40.5 Kv, Welcome worldwide customers to contact us for business and long-term cooperation. We will be your reliable partner and supplier of auto parts and accessories in China. Good Quality Transformer Substation and Switchgear, Strict quality control is executed in each link of the whole production process.We sincerely hope to establish the friendly and mutual-beneficial cooperation with you. Based on high quality solutions and perfect pre-sales /after-sales service is our idea, some clients had cooperated with us for more than 5 years.

The overall structure of the circuit breaker is simple and reasonable, and the arc extinguishing chamber part, interlock part and operating part are arranged up and down. Special spring operating mechanism, no need to adjust, stable and reliable action.The installation form is free and flexible, including the drawout type of installation and fixed type of installation for switchgears.

Environmental conditions:

  1. Altitude: the altitude does not exceed 2000m;
  2. Ambient temperature: no higher than +40℃, not lower than -25℃;
  3. Relative humidity: the daily average does not exceed 95%, and the monthly average does not exceed 90%;
  4. Earthquake intensity: no more than 8 degrees;
  5. Locations without fire, explosion hazard, serious contamination, chemical corrosion and severe vibration.

Technical parameters

Name

Unit

Value

Rated voltage

KV

40.5

1min power frequency withstand voltage

KV

95

Lightning impulse withstand voltage

KV

185

Rated frequency

Hz

50

Rated current

A

1250,1600,2000

Rated short-time withstand current

KA

25,31.5

Rated peak withstand current

KA

63,80

Rated short circuit duration

S

4

Rated short-circuit breaking current

KA

25,31.5

Rated short circuit closing current

KA

63,80

Rated operation sequence

 

0-0.3s-Co-180s-Co

Break time

ms

<80

Rated operating voltage

V

~110/-110,~220/-220

Mechanical life

time

10000

12.png