8615167740056

 Disconnector,Outdoor serial High Voltage isolator,Medium Voltage Isolator Wholesale 12kv 24kv 36kv GW5

GW5 Type serial High Voltage isolator
High-voltage Alienating Disconnecting Switches and Earthing Switches,IEC62271-102:2002AC Disconnecting Switches and Earthing Switches ,and IEC60694:1996 Common Clause for High voltage Switchgear and Control Devices.
Request a Quote

PRODUCTS DETAILS

product detail

Product Description

 

GW5 Outdoor serial High Voltage isolatorProduct Description

GW5 Type serial High Voltage isolator  the series of  disconnecting switches comply with requirements in GB1985-2004.

 High-voltage Alienating Disconnecting Switches and Earthing Switches,IEC62271-102:2002AC Disconnecting Switches and Earthing Switches ,and IEC60694:1996 Common Clause for High voltage Switchgear and Control Devices.

Product feature

1.Complete in specifications,high technical parameters is high, wide range. Additional, wide scope of application , it can be used for high layout. Installation way is flexible. 

2.Perfect sealing Performance and  Resistant To Rust 

3.Simple, reliable mechanical rotating way. 

4.Perfect dustproof, waterproof, and anti-corrosion ability. 

5.Full set of steel galvanized foundation frame and the vertical and horizontal  dwang for option.

Service Conditions:

? Altitude:1000m~3000m

?Ambient temperature:-30°C ~-40°C

?Wind pressure:≤700pa(wind speed 34m/s)

?Earthquake intensity:≤8 degree

?Rative humidity of air:monthly≤90°C,daily≤95°C

?Environment degree: degree III

?Cannot be use on the condition of the danger of fire and blast,heavy pollution,chemical etching,strong shake ect.

Technical parameter

No

Items

Technical parameter 

1

Rated Voltage                         kV

 

33 ,35,36,40.5

72.5

2

Nominal system   voltage         kV

 

35

66

3

Rated   current           A

630;1250;1600;2000;2500;3150;4000

4

Rated Short Time withstand current and   Time            kA/s

25~50/4

5

Rated Peak withstand   current                kA

63~125

6

1min power frequency  withstand   voltage (effective value)    kV

To earth

95/85

140

To phase

95/85

140

Across Isolating DS

118

180

7

Lightning Impulse wishstand voltage(peak   value) KV

To earth

185

325

To phase

185

325

Across Isolating DS

210

385

8

Rated mechanical terminal load              N

Level of lateral load

500

750

Level of vertical load

250

500

Vertical

500

750

9

The min distance of insulation against   ground      mm

300

500

 

10

Max Man Operative Moment            N. m

200

11

Motor Drive operating mechanism control   voltage                   V

AC220,380; DC110,220

12

Motor Drive operating mechanism motor    voltage                      V

AC220,380; DC110,220

 

 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return